We're sorry, but the RESET website does not work properly without JavaScript enabled. Please enable JavaScript to continue.
RESET

RESET® 空气项目

The RESET Air Standard is the world's first sensor-based and performance-driven data standard and certification program for the built environment.

RESET Air standardizes the continuous monitoring requirements of air quality in built environments and makes visible the invisible factor that impacts all indoor spaces in regards to health, productivity, and sustainability.

Go to RESET Air Projects Process

1. Why do a RESET Air Project

RESET Air establishes monitoring requirements and performance targets for healthy indoor air quality. RESET Air's requirements for continuous monitoring can be used to determine whether or not a space is healthy and can also help a project optimize the solutions to guarantee that it is healthy. With a focus on monitoring rather than specific solutions, this approach maximizes innovation and adaptation while reducing overall project costs.

The RESET framework brings buildings into the age of data. A building and an organization that understands data has significant benefits:

Promoting Health and Productivity

We breathe 15,000L of air per day. We consume 5,000 times more air than water in terms of volume. Minor variations in air quality dramatically impacts health and productivity.

RESET empowers healthier and more productive buildings and occupants, which is vital to retaining tenants and employees, in addition to attracting new ones.

RESET Air provides a tangible return on investment for offices and property owners. For offices, RESET Air enables healthier spaces and more productive spaces. For property owners, RESET Air empowers the communication of healthier, more productive buildings to prospective tenants.

To learn more about the effects of air quality, download the RESET Air Introduction PDF .

Servicing Guarantee

When working with air quality service or solutions providers, RESET Air is an excellent way to guarantee the service being offered will actually result in a space with healthy air quality for the long term. Attaching RESET Air into the contract will facilitate communication and better results.

For more benefits, please go to RESET Project Benefits.

2. How RESET Air Works

RESET Air is designed to prioritize on-going results and long-term occupant health with a focus on the operational phase of the built environment. In the case of RESET Air, indoor air quality data is required to be continuously gathered through air quality monitors that measure the following parameters:

  • Particulate Matter (PM2.5 in ug/m3)
  • Total Volatile Organic Compounds (TVOC in mg/m3, ug/m3 or ppb)
  • Carbon Dioxide (CO2 in ppm)
  • Temperature (in °C or °F)
  • Relative Humidity (in %RH)

RESET Air employs a non-prescriptive approach for certification. Given the wide variety of space types occurring in the built environment and myriad ways occupants use these spaces, project teams must define and defend their calculation methodologies based on the individual project.

Below are summaries of the project accreditation requirements for the two project typologies:

At a Glance - Commercial Interiors

RESET Air for Commercial Interiors (CI) tracks and communicates the health performance of interiors to occupants. Commercial Interiors targets a section of the interior space and is a typology tailored for tenants or a partial owner of an indoor space.

Real-time results are used to attract and retain the best staff, reduce insurance premiums, increase occupancy rates and ensure occupants stay healthy.

Monitoring Requirements

  1. Minimum of one space out of every regularly occupied space type.
  2. 80% of occupants represented.
  3. Monitor coverage not to exceed 500m2 in open areas.
  4. Use of accredited hardware & software platforms.

Performance Requirements

Continuous monitoring of PM2.5, CO2, VOCs, RH and Temperature. Thresholds for PM2.5, CO2 & VOCs attained for 3 months consecutively.

Communication & Education

Performance results available to long-term project occupants on an ongoing basis, once performance thresholds are met.

Check out the RESET Air Project Process page or go download the pdf at the download section, 2.3 RESET Air Certification Process for Commercial Interiors.

At a Glance - Core & Shell

RESET Air for Core & Shell (CS) tracks and communicates the health performance of entire buildings to prospective tenants. Core & Shell targets the entire building and is a typology tailored for landlords and developers.

Real-time results helps owners attract better tenants, maintain asset value and reduce the potential liability associated with under-performing buildings.

Monitoring Requirements

  1. Monitors installed post-filtration and post-mixing to monitor the air being delivered to occupants.
  2. 30% of delivered air monitored.
  3. Pairing with an outdoor air quality monitor, used to establish an outdoor baseline for comparison.
  4. Use of accredited hardware & software platforms.

Performance Requirements

Continuous monitoring of PM2.5, CO2, VOCs, RH and Temperature. Thresholds for PM2.5, CO2 & VOCs attained for 3 months consecutively.

Communication & Education

Performance results available to long-term project occupants on an ongoing basis, once performance thresholds are met.

Check out the RESET Air Project Process page or go download the pdf at the download section, 2.5 RESET Air Certification Process for Core & Shell.

RESET can be applied to new or existing project typologies.

By separating Commercial Interiors and Core & Shell, RESET Air helps owners, operators, and tenants achieve healthy performance targets by clearly defining and communicating their respective roles and responsibilities.

3. Implementation and Considerations

Getting started with RESET Air is easy, low commitment, and low cost because it is only targeting continuous monitoring and data collection, not the solutions. Leveraging the data collected will allow projects to be able to find the best and most cost effective solution for the situation.

The general process for RESET Air projects can be broken down into the following four parts:

计划和选择室内空气质量 (IAQ) 监测方案

作为性能为依据的标准,RESET 从集成经认可的 IAQ 传感器和监测设备开始。RESET 为监测设备性能、安装、标定和数据报告制定了标准。RESET 对硬件品牌选择没有限制,唯一的要求就是符合我们的 IAQ 监测设备测试。让 RESET AP 帮您选择符合要求的 IAQ 监测设备,选择安装位置并制定维护计划。

RESET AP 在该阶段并非强制要求,但 RESET AP 的介入大大增加了项目达到认证要求的可能性。

Click here to browse through the directory of RESET Accredited Monitors and RESET Accredited Data Providers.

安装并调试室内空气质量 (IAQ) 监测设备

为了达到 RESET 要求,必须正确安装和调试监测设备。监测设备必须经过标定,其网络必须经过正确配置,将实时数据传输至云端供健康和认证分析使用。

记录和认证

根据 RESET 标准,室内空间必须连续三个月在用户使用阶段符合 PM2.5、CO2、TVOC 等的健康范围,方能获得认证。

Click here to browse through our list of RESET APs.

再认证

因为 RESET 认证针对的是项目运营,项目必须每年进行再认证。作为性能为依据的标准,再认证主要以数据为基础。再认证包括半自动的数据审核以确保使用空间在健康范围内、再认证证明,以及场地审查。

4. Accreditation Process

The RESET Air Standard highlights the requirements necessary for proper air quality monitoring, so simply leveraging the standard is a good way to get started. RESET also provides third-party project accreditation and certification services, so if a project wants to achieve certification status, it is possible to do so.

RESET Air Audits

There are three parts to the RESET Air Audits:

  1. Documentation Audit

    A one-time paper audit to confirm that the implementation fulfills all of the RESET requirements.

  2. Site Audit

    A one-time physical or virtual audit to confirm that the implementation is according to what was written in the Documentation Audit.

  3. Data Audit

    A continuous data audit that verifies that the project is being continuously monitored and whether or not it is achieving performance targets.

For more details on certification, please check out RESET Air Project Accreditation Process .

Project Accreditation Statuses

Implementing monitoring according to the RESET Air Standard with no other RESET services is a good way to start. To celebrate projects that do go through the auditing and accreditation process, we have Project Accreditation Statuses that are awarded to projects:

  1. RESET Air Pre-Accredited

    Awarded to projects that have designed in to their project the requirements for continuous monitoring. To get this status, projects must pass the Documentation Audit.

  2. RESET Air Accredited

    Awarded to projects that are continuous monitoring according to the RESET Standard. To get this status, projects must pass the Site Audit and initiate and maintain the Data Audit.

  3. RESET Air Certified

    Awarded to projects that have achieved the performance requirements. To get this status, projects must pass 3 consecutive months of the Data Audit.

Accreditation Statuses are applied to each of the RESET Standards separately per project.

Click here to learn more about Project Statuses.

5. 价格

请点击以下链接查看项目价格信息。项目价格页面包括:

  1. 项目价格计算机
  2. 价格对比表格
前往 RESET 项目价格页面

6. Crosswalks

RESET Air has approved pathways, harmonizations, crosswalks and equivalencies with a host of other green building schemes and certification programs. To find out more, click the links below.

7. FAQ and Relevant Links

Below is a link to the FAQ for the RESET Air Standard & Projects and a few other relevant links:

RESET Air FAQ

RESET Air Standard & Project Links

RESET AP Links

RESET Data Provider Links

RESET Monitors Links

If you have any additional questions, please don't hesitate to reach out to us at info[at]reset.build.