RESET® 空气 for Monitors
The following section lists a summary of the changes that have been made to each standard document.
For download links, click here.
For a list of all the Change Log pages, click here.
RESET Air Standard for Monitors
Summary of Updates made for the RESET Air Standard for Accredited Monitors from v2.0 to v2.1:
- "Accuracy" is now "Relative Accuracy" based on current testing methodology.
- Officially introduces Trust & Transparency Score.
- Officially introduces Alternative Pathways.
- Re-wrote introduction section.
- Added Testing Disclaimer and Limitations section..
- Cleaned up text and removed extraneous words and explanations.
Page by Page Updates
Table of Contents
- Removed “TM” from all instances of RESET
- Added “Purpose and Approach”
- Changed “RESET Air Accredited Monitor Certification” to “Accreditation Requirements and Process”
- Added "Trust & Transparency Score"
- Added "Alternative Pathways"
2.6.0 Preface
- Added context to RESET Air Projects and updated wording
- Listed out intent
2.6.1 Introduction
- New section: Explain the connection between RESET Air Standard and RESET Air Monitors
- Establish what the RESET Air Standard for Accredited Monitors defines
2.6.1.1 Purpose & Approach
- New section: Purpose and Approach
- Purpose is to establish the connectivity and performance requirements for RESET Projects
- Approach is to list out minimum requirements based on industry best practices and available technology
2.6.1.2 Typologies and Usage
- New page describing the two Typologies and how they are used
- Added Description of the two different standards (Interiors and Core & Shell)
- Added relationship between tenant and landlord
- How typologies use monitors
2.6.1.3 Monitor Types
- Updated monitor descriptions
- All monitor types can be tested and accredited
2.6.2 Monitor Requirements
- New page describing how the system works and an introduction to the basic and sensor requirements for RESET Air Accredited Monitors
2.6.2.1 Basic Requirements
- Updated Introduction text
- Removed Specifications for Grade A and Grade C monitors
2.6.2.2 Sensor Requirements Introduction
- A new page to establish the sensor requirements structure first
- Added “Sensor Type/Technology and Brand/Make”
- Updated “Measuring Range” to “Measuring Range (min)”
- Added “Measuring Range (max)” row
- Updated row numbering
- Updated “Accuracy” to “Relative Accuracy”
- Removed “Performance Check”
- Updated “Re-calibration” to “Re-calibration Capability and Auto Re-calibration”
- Terms & Descriptions
- Removed Sampling Type. Unnecessary with the way we do testing
- Added “Sensor Type/Technology and Brand/Make”
- Changed “Sensor Output Resolution” to “Output Resolution”
- Updated text for “Measuring Range (min)”
- Added “Measuring Range (max)”
- Updated “Accuracy” to “Relative Accuracy”
- Describe why relative accuracy over absolute accuracy
- Changed “Performance Check and Re-calibration” to “Calibration Capability and Auto-calibration”
2.6.2.3 Sensor Requirements - Particulate Matter 2.5 (PM2.5)
- Cleaned up text
- Removed Sampling Type. Unnecessary with the way we do testing
- Updated “Measuring Range (min)” from 1-500 to 1-300
- Added “Measuring Range (max)”, 1-500
2.6.2.4 Sensor Requirements - Carbon Dioxide (CO2)
- Cleaned up text
- Changed sensor output resolution to 1
- Updated“Measuring Range (min)” from 400-5000 to 400-4000
- Added “Measuring Range (max)”, 1-5000
- Updated Relative Accuracy range to match new measuring ranges
2.6.2.5 Sensor Requirements - Total Volatile Organic Compounds (TVOC)
- Cleaned up text
- Added references to California and Australia's definitions of TVOC for ug/m3
- Updated “Measuring Range (min)” from 150-2000 to 150-2500
- Added “Measuring Range (max)”, 1-5000
- Updated Relative Accuracy range to match new measuring ranges for ppb
- Updated“Measuring Range (min)” from 65-870 to 65-1100
- Added “Measuring Range (max)”, 1-2200
- Updated Relative Accuracy range to match new measuring ranges
2.6.2.6 Sensor Requirements - Temperature
- Cleaned up text
- Added “Measuring Range (max)”, No limit
2.6.2.7 Sensor Requirements - Relative Humidity
- Cleaned up text
- Added “Measuring Range (max)”, 1-99
2.6.3 Monitor Accreditation Process
- Additional options for testing (self testing and their TTS score)
- Tests require 5x Monitors to be placed in an occupied office-like environment with people moving around
2.6.3.1 Testing Disclaimer and Limitations
- New Section: Disclaimer and Limitations
- Include Disclaimer
- Include Limitations for:
- relative vs. absolute accuracy
- drift over time
2.6.3.2 Optional Parameters for Testing
- New Section: Optional Parameters
2.6.4 Trust & Transparency Score
- Introducing Trust & Transparency Score
- Needs to add a link to the TT Score page on the RESET Website
2.6.5 Alternative Pathway
- Introducing Alternative Pathways officially
- How to introduce new Alternative Pathways
2.6.5.1 Alternative Options to Interfacing with the RESET Cloud
- Specifies the different options and statuses for how monitors connect with the RESET Cloud
2.6.5.2 Alternative Data Output Interval
- Alternative options for data output interval
2.6.5.3 Alternative for Individual Sensor Parameters
- Alternative options for accrediting less or more sensors in a monitor