We're sorry, but the RESET website does not work properly without JavaScript enabled. Please enable JavaScript to continue.
RESET

RESET® 空气 for Monitors

Change Log from v2.0 to v2.1

The following section lists a summary of the changes that have been made to each standard document.

For download links, click here.

For a list of all the Change Log pages, click here.

RESET Air Standard for Monitors

Summary of Updates made for the RESET Air Standard for Accredited Monitors from v2.0 to v2.1:

  • "Accuracy" is now "Relative Accuracy" based on current testing methodology.
  • Officially introduces Trust & Transparency Score.
  • Officially introduces Alternative Pathways.
  • Re-wrote introduction section.
  • Added Testing Disclaimer and Limitations section..
  • Cleaned up text and removed extraneous words and explanations.

Page by Page Updates

Table of Contents

  • Removed “TM” from all instances of RESET
  • Added “Purpose and Approach”
  • Changed “RESET Air Accredited Monitor Certification” to “Accreditation Requirements and Process”
  • Added "Trust & Transparency Score"
  • Added "Alternative Pathways"

2.6.0 Preface

  • Added context to RESET Air Projects and updated wording
  • Listed out intent

2.6.1 Introduction

  • New section: Explain the connection between RESET Air Standard and RESET Air Monitors
  • Establish what the RESET Air Standard for Accredited Monitors defines

2.6.1.1 Purpose & Approach

  • New section: Purpose and Approach
  • Purpose is to establish the connectivity and performance requirements for RESET Projects
  • Approach is to list out minimum requirements based on industry best practices and available technology

2.6.1.2 Typologies and Usage

  • New page describing the two Typologies and how they are used
  • Added Description of the two different standards (Interiors and Core & Shell)
  • Added relationship between tenant and landlord
  • How typologies use monitors

2.6.1.3 Monitor Types

  • Updated monitor descriptions
  • All monitor types can be tested and accredited

2.6.2 Monitor Requirements

  • New page describing how the system works and an introduction to the basic and sensor requirements for RESET Air Accredited Monitors

2.6.2.1 Basic Requirements

  • Updated Introduction text
  • Removed Specifications for Grade A and Grade C monitors

2.6.2.2 Sensor Requirements Introduction

  • A new page to establish the sensor requirements structure first
  • Added “Sensor Type/Technology and Brand/Make”
  • Updated “Measuring Range” to “Measuring Range (min)”
  • Added “Measuring Range (max)” row
  • Updated row numbering
  • Updated “Accuracy” to “Relative Accuracy”
  • Removed “Performance Check”
  • Updated “Re-calibration” to “Re-calibration Capability and Auto Re-calibration”
  • Terms & Descriptions
    • Removed Sampling Type. Unnecessary with the way we do testing
    • Added “Sensor Type/Technology and Brand/Make”
    • Changed “Sensor Output Resolution” to “Output Resolution”
    • Updated text for “Measuring Range (min)”
    • Added “Measuring Range (max)”
    • Updated “Accuracy” to “Relative Accuracy”
    • Describe why relative accuracy over absolute accuracy
    • Changed “Performance Check and Re-calibration” to “Calibration Capability and Auto-calibration”

2.6.2.3 Sensor Requirements - Particulate Matter 2.5 (PM2.5)

  • Cleaned up text
  • Removed Sampling Type. Unnecessary with the way we do testing
  • Updated “Measuring Range (min)” from 1-500 to 1-300
  • Added “Measuring Range (max)”, 1-500

2.6.2.4 Sensor Requirements - Carbon Dioxide (CO2)

  • Cleaned up text
  • Changed sensor output resolution to 1
  • Updated“Measuring Range (min)” from 400-5000 to 400-4000
  • Added “Measuring Range (max)”, 1-5000
  • Updated Relative Accuracy range to match new measuring ranges

2.6.2.5 Sensor Requirements - Total Volatile Organic Compounds (TVOC)

  • Cleaned up text
  • Added references to California and Australia's definitions of TVOC for ug/m3
  • Updated “Measuring Range (min)” from 150-2000 to 150-2500
  • Added “Measuring Range (max)”, 1-5000
  • Updated Relative Accuracy range to match new measuring ranges for ppb
  • Updated“Measuring Range (min)” from 65-870 to 65-1100
  • Added “Measuring Range (max)”, 1-2200
  • Updated Relative Accuracy range to match new measuring ranges

2.6.2.6 Sensor Requirements - Temperature

  • Cleaned up text
  • Added “Measuring Range (max)”, No limit

2.6.2.7 Sensor Requirements - Relative Humidity

  • Cleaned up text
  • Added “Measuring Range (max)”, 1-99

2.6.3 Monitor Accreditation Process

  • Additional options for testing (self testing and their TTS score)
  • Tests require 5x Monitors to be placed in an occupied office-like environment with people moving around

2.6.3.1 Testing Disclaimer and Limitations

  • New Section: Disclaimer and Limitations
  • Include Disclaimer
  • Include Limitations for:
    • relative vs. absolute accuracy
    • drift over time

2.6.3.2 Optional Parameters for Testing

  • New Section: Optional Parameters

2.6.4 Trust & Transparency Score

  • Introducing Trust & Transparency Score
  • Needs to add a link to the TT Score page on the RESET Website

2.6.5 Alternative Pathway

  • Introducing Alternative Pathways officially
  • How to introduce new Alternative Pathways

2.6.5.1 Alternative Options to Interfacing with the RESET Cloud

  • Specifies the different options and statuses for how monitors connect with the RESET Cloud

2.6.5.2 Alternative Data Output Interval

  • Alternative options for data output interval

2.6.5.3 Alternative for Individual Sensor Parameters

  • Alternative options for accrediting less or more sensors in a monitor